PD10

Reticle / Mask Particle Detection System

Next-generation inspection platform to meet future needs

PD10 is the latest generation of the HORIBA Particle Inspection product line. Based on an innovative modular platform design, PD10 is the right tool to meet current and future needs of Mask & Pellicle inspection in the lithography and mask production processes. Fab automation, combined with a suite of HORIBA’s core technology, allow users to expand the PD10 system to include not only particle inspection and detection, but also particle characterization by Raman analysis, pellicle film thickness and uniformity, and pellicle health monitoring tools.

Segment: Semiconductor
Division: Metrology
Fabricant: HORIBA, Ltd.

Sélection de pays et territoires où ce produit est disponible:
China,Germany,Ireland,Israel,Italy,Korea (South),Malaysia,Singapore,Taiwan,United Kingdom,United States
Voir la liste complète ici.

  • Adjustable detection sensitivity by utilizing a combination of optical systems
  • OHT, EFEM, multi-port, multi-slot adaptation
  • Ability to reanalyse inspection data for faster inspection recipe optimization
  • Integration options with other HORIBA sensor products like Raman spectroscopy and Ellipsometry
  • False detection reduction function
  • Innovative software with improved usability
Model   PD10
Dimensions (W) x (D) x (H) 1,000 x 1,850 x 1,600 mm
Weight Approx. 950kg
Inspection Particle Size Pattern 0.5 μm / 0.35 μm (0.1 μm : Blank Mask)*¹
Glass 5.0 μm (0.5 μm - : High Sensitivity Option)*¹
Pellicle 10.0 μm (0.5 μm - : High Sensitivity Option)*¹
Light Source 633 nm He-Ne laser or 488 nm Solid-state laser
Reticle Size 5 inch - 9 inch
Case openers SMIF POD, Compatible with various cases
Throughput Approx. 12 min (From inspection start to test result display for 2 surface (6 inch) inspection)
Panel Surface Treatment Stainless Steel
Installation Environment Cleanliness Class6 ISO standards or better 
Temperature 23 +/- 1°C
Utilities Power AC200-240 V, 2 kVA 50/60Hz, Single Phase
Vacuum Source Pressure -80 kPA or less
Compressed Air 0.6 MPa - 0.7 MPa

New Function / Option

Reticle Edge Handling Yes
Auto Capture / Auto Sizing Yes
Data Browser Function Yes
False Detection Reduction Function Yes

*PSL equivalent , HORIBA recommends customer sample test for inspection sensitivity validation.

 

Demande d'informations

Vous avez des questions ou des demandes ? Utilisez ce formulaire pour contacter nos spécialistes.

* Ces champs sont obligatoires.

Related products

ANALYSETTE 28 ImageSizer*
ANALYSETTE 28 ImageSizer*

Dynamic Image Analysis

Eyecon2™*
Eyecon2™*

Direct Imaging Particle Analyzer

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

Analyseur de nanoparticules

Partica LA-960V2
Partica LA-960V2

Granulomètre par diffusion laser

Partica mini LA-350
Partica mini LA-350

Granulomètre par diffusion laser

RP-1
RP-1

Reticle/Mask Particle Remover

SA-9600 Series
SA-9600 Series

BET Flowing Gas Surface Area Analyzers

Série SA-9650
Série SA-9650

Analyseurs de surface spécifique BET

ViewSizer 3000
ViewSizer 3000

Simultaneous Multispectral Nanoparticle Tracking Analysis (NTA)

APDA-372
APDA-372

Ambient Dust Monitor

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

Analyseur de nanoparticules

Partica LA-960V2
Partica LA-960V2

Granulomètre par diffusion laser

Partica mini LA-350
Partica mini LA-350

Granulomètre par diffusion laser