FTX-ONE - FTIR Exhaust Gas Analyzer
Vue d'ensemble
The World’s smallest Device*1 in its class for the simultaneous measurement of multiple components of engine exhaust gas.
The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from un-diluted exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.
*1 HORIBA Checked on May 2018 2018 as smallest footprint
Fonctions
- Low sample flow rate but fast response.
Whilst maintaining high accuracy by the use of a high performance compact gas cell.
Multi-point exhaust sampling and ideal for catalyst evaluation in combination with a simulated exhaust gas generator. - Approx. 50%*2 smaller footprint and reduced weight in comparison to a conventional laboratory FTIR.
More Flexibility in cell layout and easier access for maintenance. - At the Core of the Instrument - In-House Knowledge
The analyzer is the core of an emission measurement system and the key to accurate measurement. HORIBA maintains excellent quality by manufacturing analyzers “in-house” and designs for operation & maintenance efficiency.
*2 Compared to our conventional product
Featured Applications
- Evaluation of catalysts, SCR systems and NOx traps
- Evaluation of biofuel exhaust (alcohol etc.)
- Compliance to EURO VI and the latest European regulations
Fabriqué par HORIBA
Caractéristiques
Components and ranges*1
Components | Standard |
---|---|
CO | 0-200ppm |
CO2 | 0-1 vol% |
NO | 0-200ppm |
NO2 | 0-200ppm |
N2O | 0-200ppm |
H2O | 0-24 vol% |
NH3 | 0-100ppm |
SO2 | 0-200ppm |
HCHO*2 | 0-500ppm |
HCOOH | 0-100ppm |
CH4 | 0-500ppm |
C2H4 | 0-500ppm |
C2H6 | 0-200ppm |
C3H6 | 0-200ppm |
1,3-C4H6 | 0-200ppm |
iso-C4H8 | 0-200ppm |
C6H6 | 0-500ppm |
C7H8 | 0-500ppm |
(NO+NO2) | Sum of NO and NO2 |
*1 The following are optional: Add other components (methanol, ethanol, acetaldehyde, MTBE, DME, acetone and acetic acid), to interchange other components and to change ranges. Please contact HORIBA for optional arrangements.
*2 For reference
Outline
Measurement target | exhaust gas from internal combustion engine (Direct measurement) |
---|---|
Target components and ranges | Max. 28 components*3 |
Principle | Fourier Transform Infrared (FTIR) |
Sampling line temperature | 113 ± 6 °C or 191 ± 6 °C |
Sampling gas flow rate | 3.5 L/min |
Operating environment | Ambient temperature: 5 to 40°C, Ambient humidity: less than 80% relative humidity (non condensing) |
Power requirements *4 | Approx. 2.8 kVA as MAX., Approx. 2.2 kVA at stable state |
Dimensions | 450 (W) X 700 (D) X 1000 (H) mm*5 |
Mass | Approx. 150 kg*5 |
Performance
Zero noise | 0.5 to less than 2% of full scale (depending on measurement components)*6 |
---|---|
Response (t10-90) time | 1.5 seconds or less when switching from N2 to 200ppm CO |
Repeatability *8 *9 | Within ± 1.0% of full scale |
Zero drift / Span drift *8 *9 | Within ± 1.0% of full scale / 8 hours |
Option
Automatic replenishing device for liquid nitrogen | Max. storage amount: Approx. 12 L |
---|---|
Vacuum side leak check |
*3 To be specified when ordering
*4 Using a heating filter and a heating pipe (15 m).
*5 Excluding protruding objects
*6 The zero noise is defined as the standard deviation of the concentration reading multiplied by 2.
*7 Using a sample probe (0.3 m), a heating filter and a heating pipe (15 m) without obvious dirt in a sample line.
*8 Confirmed with 200ppm CO, 500ppm CH4 and 500ppm C2H6
*9 Span gas with more than 80% of the full scale concentration shall be used.
Applications
- Evaluation of catalysts, SCR systems and NOx traps
- Evaluation of biofuel exhaust (alcohol etc.)
- Compliance to EURO VI and the latest European regulations
- Engine Testing in Automobiles and Components
- Vehicle Certification in Automobiles and Components