Motor Exhaust Gas Analyzer

MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture. The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.

事業部: Automotive
製造商: HORIBA, Ltd.

 Calendar Timer Function
The start time and end time of the instrument can be set for each day of the week. A warm up sequence and a purge are carried out automatically.

 Self-Diagnosis Function 
Instrument parameters such as sample flow rate and temperature of the electronic cooler are monitored to ensure highly accurate and reliable measurements.

 Measurement Value Judgment Function
Using AUTO mode, measurement, judgment and then purge are made continuously.

Small Footprint 
11% smaller than previous model. Good design allows it to fit into any workspace.

Model MEXA-1300R 
Compatible standardsCE, FCC (Class A)
Reference standard OIML R99 Class 0
Analyzing target Exhaust gases of two-cycle and four-cycle engines
Measurement item and 
range
CO : 0.00% vol - 10.00% vol
HC : 0ppm vol - 10,000ppm vol (N-hexane)
CO2 : 0.00% vol - 20.00% vol
AFR : 10.0 - 30.0
Lambda : 0.500 - 2.500
O2 : 0.00% vol - 25.00% vol (Optional)
Principle / Calculation 
method
CO, CO2, HC : NDIR (Non-dispersive infrared gas analysis) 
O2 : galvanic cell type sensor
AFR, Lambda : carbon balance method or Bretschneider 
method (When O2 sensor is embedded)
Operating environmentTemperature : 5 °C - 35 °C
Humidity : 85% RH or less (No condensation)
Atmospheric pressure : 86 kPa - 106 kPa
ConfigurationMain body (Analysis unit, control unit, display integrated
in main body)
Communication 
interface
HOST (RS-232C) : D-sub 9 pin (Male)
HOST (LAN) : RJ-45
Analog output : D-sub 9 pin (Female) 0 - 1 V 6 ch(Optional)
Power supplyAny of the following voltage and frequency
(To be specified when ordering)
100±10 V AC, 50 / 60 Hz±1 Hz, single phase
110±11 V AC, 50 / 60 Hz±1 Hz, single phase
115±11.5 V AC, 50 / 60 Hz±1 Hz, single phase
120±12 V AC, 60 Hz±1 Hz, single phase
200±20 V AC, 50 / 60 Hz±1 Hz, single phase
220±22 V AC, 50 Hz±1 Hz, single phase
230(207 - 250)V AC, 50 Hz±1 Hz, single phase
240(216 - 250)V AC, 50 Hz±1 Hz, single phase
Power consumptionApprox. 250 VA (100 V AC - 240 V AC)
DimensinonsApprox. 430 (W) x 400 (D) x 900 (H) mm
MassApprox. 60 kg

留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

Related products

CVS-ONE
CVS-ONE

Constant Volume Sampler

EXFM-ONE
EXFM-ONE

Ultrasonic Exhaust Flow Meter

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-730λ
MEXA-730λ

Air-to-fuel Ratio Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PM unit
OBS-ONE PM unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

AP-380 Series
AP-380 Series

Air Quality Monitor

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

TCA-5000
TCA-5000

Hydrogen Gas Analyzer

Corporate