EMIA-20XC

High-Concentration Carbon Analyzer

Highly Repeatable Carbon Analysis for Precise Control of High-Carbon Materials

Precise control of carbon concentration is critical in the production of tungsten carbide and other carbon-containing powders. 
The EMIA-20XC from EMIA-Expert series is designed for the precise analysis of high-carbon-content materials, delivering accurate, highly repeatable results and reliable long-term reproducibility. Its dedicated XC detection unit, optimized for high-carbon applications, minimizes the effects of atmospheric pressure and temperature fluctuations, enabling consistent measurements in a short time. The built-in switching function also enables the analysis of carbon and sulfur at low-ppm concentrations, combining high-concentration carbon analysis with versatile carbon/sulfur measurement in a single system.

Main Features

  •  RSD ≤ 0.15% and approximately 160 seconds in XC Mode

In XC Mode, the analyzer achieves a relative standard deviation (RSD) of ≤ 0.15% for high-carbon-content materials such as tungsten carbide. Results are displayed in approximately 160 seconds from measurement start.

  •  2-in-1 Cemented Carbide Carbon and Inorganic Carbon /Sulfur Determination

By switching the modes, the EMIA-20XC supports both high-concentration carbon analysis and low-concentration carbon and sulfur analysis.

  •  Optional autosampler is available.
事業部: Scientific
製造商: HORIBA, Ltd.

Proprietary Technology for High-Repeatability Measurement 

  • The detection unit (XC unit), specialized for measuring high-carbon-content materials, minimizes the effects of atmospheric pressure and room temperature fluctuations, enabling high-repeatability measurements in a short time. 
  • Relative standard deviation (RSD) ≤ 0.15%, demonstrating outstanding reproducibility, for high-carbon-content materials, such as tungsten carbide.
  • Approximately 160 seconds from measurement start to results display: high-repeatability measurement mode (XC mode).


The Gas Flow

The EMIA-20XC enables switching between high-repeatability measurement of high-concentration carbon and measurement of low-concentration carbon and sulfur. 


Applications*

*Application examples are based on representative evaluations conducted with EMIA-20XC and/or EMIA-Pro/Expert. Results and repeatability depend on sample composition, homogeneity, concentration, particle size, pretreatment, calibration, and other measurement conditions. The specified RSD  0.15% applies only under the specified measurement conditions and is not guaranteed for all sample types. Please contact HORIBA before purchase to confirm the feasibility of your application and recommended measurement conditions.

 

 

EMIA-Expert series: EMIA-20XC Specifications by Operating Mode
 XC ModeStandard Mode
Measurement PrincipleHigh-frequency induction furnace combustion – infrared absorption method
Sample MassMax 0.50 or less than 0.49 ± 0.01 gLess than 1.00 ± 0.10 g
Measurement Time (Average)Approx. 160 secondsApprox. 60 seconds
CarbonMeasurement Range *21.0% - 20.0%0.6 ppm - 10.0%
Reproducibility *3

RSD ≤ 0.15%

σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.5% (Sample more than 20 ppm)
SulfurMeasurement Range *2-0.6 ppm - 1.0%
Reproducibility *3-σ ≤ 0.3 ppm (Sample less than 20 ppm),
σ ≤ 1 ppm or RSD ≤ 0.75% (Sample more than 20 ppm)

Utility

Carrier GasOxygen (Purity: 99.5% or higher, 0.30 - 0.33 MPa)
Operation GasNitrogen (Purity: 99.5% or higher, 0.40 - 0.45 MPa)

Dimensions (W x D x H mm) and Mass (kg)

Main Unit500 x 725 x 710 mm/approx. 134 kg*4
Purifier/Oxidizer160 x 560 x 512 mm/approx. 28 kg
XC Unit260 x 560 x 513 mm/approx. 37 kg

*1 Varies depending on the sample, measurement conditions, and options.
*2 Maximum range is extended by reducing the sample mass.
*3 Guaranteed values apply and are limited to the following conditions: When using reliable standards and using official consumables (accelerators, crucible, reagents, others).
*4 Excludes protrusions on the rear panel.

Available Options

  • Auto Sampler

Up to 20 samples can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. Measurements can also be manually interrupted when necessary. 

 

 

  • Halogen Trap Unit

HT-03 Traps halogen derived from sample, allowing analysis with minimized influence.can be loaded. The system automatically places crucibles in the furnace and disposes of them after measurements. 

 


留言諮詢

如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。

* 這些欄位為必填項目。

更多推荐

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

AP-380 Series
AP-380 Series

Air Quality Monitor

BE-150
BE-150

OEM gas (CO/HC) analyzer

BE-220FSD
BE-220FSD

OEM gas (NO) analyzer

CCEVA
CCEVA

Carbon Capture Evaluation System

EMGA-Expert (EMGA-21E)
EMGA-Expert (EMGA-21E)

Hydrogen Analyzer EMGA Series
(Flagship High-Accuracy Model)

EMGA-Expert (EMGA-30E/20E)
EMGA-Expert (EMGA-30E/20E)

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro (EMGA-20P)
EMGA-Pro (EMGA-20P)

Oxygen/Nitrogen Analyzer (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer
(Flagship High-Accuracy Model)

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer (Entry Model)

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer (Tubular Electric Resistance Heating Furnace Model)

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

IR-300 Series
IR-300 Series

Vapor Concentration Monitor

IR-400 Series
IR-400 Series

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

TCA-5000
TCA-5000

Hydrogen Gas Analyzer

Corporate