EMGA-Expert (EMGA-21E)

Hydrogen Analyzer EMGA Series
(Flagship High-Accuracy Model)

EMGA-Expert (EMGA-21E) specializes in ultra-trace hydrogen analysis below 1.0 ppm, equipped with a high-sensitivity TCD (thermal conductivity detector) and HORIBA’ s proprietary gas separation column for R&D and quality control of iron and steel, nonferrous metals, and ceramics.

Hydrogen is a critical element in material development and quality control, as even extremely small amounts can cause defects in materials. However, analyzers capable of detecting hydrogen at the 0.1 ppm level remain limited. The “Inert Gas Fusion – Thermal Conductivity Detection” method has proven to be a highly effective technique for such ultra-trace analysis. HORIBA has over 40 years of experience in developing analyzers based on this method, and has built proprietary technologies such as an impulse furnace for sample heating and melting, a high-sensitivity thermal conductivity detector (TCD), gas separation technology, and advanced control systems. The EMGA-Expert Hydrogen Dedicated Analyzer (EMGA-21E) is an ultra-trace hydrogen analyzer that delivers high-precision analysis along with excellent usability, simple maintenance, and low running costs.

Typical Applications:
- Steel and non-ferrous alloy (metallurgy): 
Iron, titanium, zirconium, tantalum, copper, nickel, aluminum, zinc, and tungsten carbide
- Semiconductor: Silicon
- Other: Carbon black

事业部: 科学仪器
制造商: HORIBA, Ltd.

The Gas Flow

In the measurement method of EMGA-Expert Hydrogen Analyzer, a sample placed in a crucible is subjected to electrical heating to melt and gasify the elements present in the sample. Argon (Ar), an inert gas, is used as a carrier gas to transport the gasified elements to the TCD detector which ensures exceptional analytical accuracy and stability of the contained elements and their concentration in the gas.

Enlarge gas flow diagram
 


 

Improved Maintainability

Reduces maintenance work hours and frequency with new mechanisms for replacing consumables

■ Dust filter*   *Patent-pending

With its new mechanism for replacing the dust filter, the operator only needs to replace the thin filter inside the filter holder.This has also reduced the filter replacement frequency to one-fifth (replacement is required approximately every 250 uses).

■ Replacement of electrodes and reagent tube

The integrated upper electrode and reagent tube are easy to remove for easy maintenance.


 



Reduced Costs

Significantly reduces carrier gas* consumption by 25%, compared to consumption of conventional models   *Inert gas that transports the extracted gas from the sample to the detector

Customer Feedback “Reduced carrier gas consumption reduces the man-hours required to replace gas cylinders.”
(The eff­ectiveness may vary depending on measurement conditions, analysis frequency, and standby time.)
 



Enhanced Usability

3 navigation functions enhance analyses

Maintenance Navigation

Provides navigation for maintenance tasks, procedures, and methods.                                                                                     

Troubleshooting Navigation

Provides navigation for the optimal recovery method with image-based explanations from alarm display to equipment recovery.

Analysis Navigation

Provides step-by-step support for all users, guiding them through the operating procedures and conditions.

The EMGA Pro/Expert Series has its original operation software* which prioritized ease of use, specifically in navigation functions.
*The user interface and functionalities of the software for this system are the same with those of EMIA/EMGA series
 



Automation Options

We provide three optional automation units for streamlining your operation for the EMGA Series:
- Crucible Loader: Precise capture and positioning of crucibles by rotary mechanism. Maximum stock: 100 pcs.
- Auto Sampler: Samples and fluxes are automatically loaded (Up to 22).
- Auto Cleaner: Two rotating brushes clean the upper and lower electrodes after each measurement.
 
Please refer the Automation Options and other optional units for the EMIA/EMGA Pro/Expert Series Elemental Analyzers for the details.

Measurement target elemetHydrogen
Measurement gas typeH2
DetectorTCD
Measurement range*
*Up to 100% wt is possible by decreasing the sample weight
0.04 ppm-0.02%
Precision /
Repeatability
σn-1-≦0.04 ppm or CV≦0.5%(GAS)
Sample weight1.0 g*          *Possible to decrease.
Cycle time*
*From the start of measurement to auto-cleaning and crucible supply.
Approx. 280 sec (According to our standard conditions)
Required gasCarrier gas
Ar: Purity greater than 99.995%, Pressure 0.35 MPa (Stainless steel tube O.D.3 mm and suitable connector fitting within 3 m from the unit)
Operation gas
Dry air or N2 as operating gas: Pressure 0.45 MPa (Nylon pipe O.D.Connection of φ6/4 mm nylon pipe within 5 meters of the main unit).
Dimensions*
*Dimensions exclude pipework and other protrusions.
655 x 710 x 725 mm [W x H x D] 
WeightMain unit: 197 kg (Furnace unit: approx.127 kg / Measurement unit: approx.70 kg)
Cleaner unit: approx. 28 kg / Radiator unit: approx. 33 kg
PowerMain unit: AC 200/220/230 ±10% 50/60 ±1 Hz 12 kVA (MAX)
Vacuum cleaner: AC 100V (Step-down transformer included) 50/60 ±1 Hz 1.5 kVA (MAX)

 

Optional Units for Multiple Applications

Gas conversion unit (C-50)

This unit converts the generated sample gas into a measurable gas (CO, N2, H2) using a gas reduction method.

Capsule press machine (FP-30)

The press machine for encapsulating powder samples ensures stable encapsulation without relying on operator skill.

Auto sampler

The press machine for encapsulating powder samples ensures stable encapsulation without relying on operator skill. 

 

Halogen trap unit (HT-30)

The unit enables efficient gas conversion with additional reagents, depending on the sample.

Opening safety cover

The safety cover unit with interlock function ensures operator safety.

Additional detector unit for O / N*

Sharing the extraction unit enables high-precision oxygen and nitrogen analysis, as well as ultra-trace hydrogen analysis.
*Please contact us for details.

 

钛合金中低浓度氢含量的定量分析
钛合金中低浓度氢含量的定量分析
我们能否对钛合金中的氢进行定量分析以防止氢脆?
钢和金属中氢的分析:固体抽取或熔融
钢和金属中氢的分析:固体抽取或熔融
EMGA系列中的氢分析仪用于精确测量不同类型样品中的氢含量,如黑色金属、有色金属、半导体或电子材料。通过在惰性气体中加热熔融样品并抽取释放的氢气,再通过高灵敏度热导检测器进行分析即可得到氢的精确含量。但也可以在低于样品熔点加热的方式,在不熔融样品的情况下抽取释放的氢气从而测定氢含量。本内容是解释何时使用熔融抽取,何时使用固体抽取,其有利之处、具体应用和对应的样品。
固体样品中氢的分析
固体样品中氢的分析
每年,市场对各种样品材料中所含氢的分析需求不断增加。现在人们认识到,氢分析不仅在钢铁工业中至关重要,而且在铝、铜、钛等高纯度金属的制造以及新合金和新材料的开发中也至关重要。
钢中气体元素分析的样品制备和取样方法
钢中气体元素分析的样品制备和取样方法
气体元素成分分析对钢铁分析的质量保证
气体元素成分分析对钢铁分析的质量保证

留言咨询

如您有任何疑问,请在此留下详细需求信息,我们将竭诚为您服务。

* 这些字段为必填项。

更多推荐

EMGA-921
EMGA-921

氢分析仪

EMGA-Expert
EMGA-Expert

氧/氮/氢分析仪

EMGA-Pro
EMGA-Pro

氧/氮/氢分析仪

EMIA-Expert
EMIA-Expert

碳硫分析仪

EMIA-Pro
EMIA-Pro

碳硫分析仪

EMIA-Step
EMIA-Step

碳/硫分析仪

LabRAM Soleil
LabRAM Soleil

高分辨超灵敏智能拉曼成像仪

SLFA-60
SLFA-60

X射线荧光油中硫分析仪

SLFA-6000
SLFA-6000

X射线荧光油中硫分析仪

EMGA-921
EMGA-921

氢分析仪

EMGA-Expert
EMGA-Expert

氧/氮/氢分析仪

EMGA-Pro
EMGA-Pro

氧/氮/氢分析仪

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-200
HD-200

现场安装型溶解氧计(四线制传输)

HD-200FL
HD-200FL

现场安装型溶解氧计(四线制传输)

HD-300
HD-300

现场安装型溶解氧计(二线制传输)

HD-480
HD-480

现场安装型溶解氧计(四线制传输)

HD-960L
HD-960L

低浓度溶解氧浓度计

U-50
U-50

多参数水质分析仪

51 系列
51 系列

防爆气体分析仪

AP-370 系列
AP-370 系列

空气污染监测仪

AP-380 系列
AP-380 系列

空气质量监测仪

APCA-370
APCA-370

大气污染监测用二氧化碳监测仪

APMA-370
APMA-370

大气污染监测用一氧化碳监测仪

BE-150
BE-150

CO/HC检测平台

BE-220
BE-220

NO检测平台

EMGA-921
EMGA-921

氢分析仪

EMGA-Expert
EMGA-Expert

氧/氮/氢分析仪

EMGA-Pro
EMGA-Pro

氧/氮/氢分析仪

EMIA-Expert
EMIA-Expert

碳硫分析仪

EMIA-Pro
EMIA-Pro

碳硫分析仪

EMIA-Step
EMIA-Step

碳/硫分析仪

ENDA-600ZG
ENDA-600ZG

烟气监测系统

ENDA-7000 Series
ENDA-7000 Series

Stack Gas Analyzer

GA-370
GA-370

痕量气体分析仪

GI-700 系列
GI-700 系列

烟气分析仪

IR-300
IR-300

蒸汽浓度监测仪

IR-400
IR-400

用于腔室清洗终点监测的高级气体监测仪

IT-470F-H
IT-470F-H

高精度红外温度计[内置式]

LO-300
LO-300

油膜检测仪

MEXA-1300R
MEXA-1300R

发动机尾气分析系统

MEXA-584L
MEXA-584L

汽车尾气排放分析仪

MEXA-ONE
MEXA-ONE

整车排放气体分析仪

OBS-ONE GS Unit
OBS-ONE GS Unit

车载排放测量系统

OCMA-500
OCMA-500

油分分析仪

OCMA-550
OCMA-550

油分分析仪

PG-300 系列
PG-300 系列

便携式气体分析仪

TCA-5000
TCA-5000

通用型氢气分析仪

TX-100
TX-100

可调谐激光气体分析仪

VA-5000 / VA-5000WM 系列
VA-5000 / VA-5000WM 系列

多组分气体分析仪

Corporate