XPLORER-NS*

Total Nitrogen and Sulfur Analyzer

The XPLORER-NS was developed as a total nitrogen/total sulfur combustion analyzer, capable of handling fully automated applications for liquids, solids, and gases (including LPG samples.) Changing from the liquids & gas module to the solids module has never been easier. Just push one button and the liquids module is automatically retracted from the heated zone. No clamps or manual locks required.

To learn more about the XPLORER series, please visit our Sulfur-in-Oil videos page.

*Available in the Americas. For additional information, please contact us.

事業セグメント: 科学
製造会社: Trace Elemental Instruments

• Ultra-low detection limit, high stability and reliability due to the temperature controlled detectors and feedback control loop.
• Compact design, with the smallest footprint in the market.
• Short start-up time. (Less than 15 minutes from standby mode).
• Fast and precise measurement of liquids, solids, and gases (including LPGs).
• Automation available for each type of measurement.
• Easy to use and intuitive user interface and operational software.
• Simultaneous analysis of nitrogen & sulfur.
• Fast and easy switching between modules, resulting in high productivity.
• Complies with international standards like: ASTM, ISO, EN and IP.
• Fully automated creation of calibration curves from a single stock solution with the optional ARCHIE.
• Fast generation of sample lists and application methods.
• Low maintenance due to optimal combustion and the proper conditioning of the resulting gases produces near zero downtime.

Dimensions (width x height x depth)36 x 27.2 x 69 cm (14.2 x 10.7 x 27.2 in.)
Weight32 kg (70.5 lbs) without furnace tube and introduction module
Voltage100-240 V, 50-60 hz
Power requirement (max)1.15KW
Gas Connectors⅛” Swagelok
Gases requiredOxygen 99.6%, Argon 99.998% or Helium 99.99%
Input gas pressure3-10 bar (45-145 PSI)
Internal gas pressure1.8 bar, adjustable
Furnace voltageDual zone, low voltage
Furnace temperature (max)1150 °C (2102 °F)
Furnace coolingPulling fan with auto control
Sample introductionSolid or liquid by boat, Liquid by direct injection, Gases and LPGs by GLS
Sample sizeSolids: 5-1000 mg; Liquids: 100 μL; Gas; 10 ml; LPG; 100 μL
Semi-automatic boat/syringe driverSoftware controlled, programmable method file
Slider/shutter driverSoftware controlled
Detector NitrogenChemiluminescence
Detector SulfurXenon pulsed UV-fluorescence AFC Technology
Detector accuracyBetter than 2% CV
Detector conditioningTemperature controlled, adjustable
Vacuum pumpInternal 24 volt DC
Softwaredot.NET-based, TEIS software
Ambient temperature5-35 °C (41-95 °F) noncondensing